Big lab analyzer performance—designed for small workload labs

New from Roche Diagnostics, the cobas c 111 analyzer is designed to set the next gold standard in automated testing for small laboratories.

Designed to deliver big analyzer performance
With key components such as optics, reagents and calibrators taken from larger COBAS Integra® and cobas blood gas systems used in reference labs and hospitals, the cobas c 111 analyzer joins a family of analyzers designed to deliver consistent results from the smallest to the largest system.

Printer friendly version 

Technical Specifications
Test Throughput
(Theoretical Max)

65 tests/hour for photometry tests only 180 tests/hour for ISE tests only
Up to 100 tests/hour for mixed requests

Number of Channels
(Reagent Slots)

27 slots (or approximately 14 assays) per reagent disk, up to 8 disks
3 channels on ISE module

Programmable Parameters

Maximum 50 photometric
3 ISE tests, 10 profiles

Sample Types

Serum, plasma, urine, whole blood (HbA1c)

Sample Input (Sample Disk)

Load capacity:

8 positions, continuous loading

STAT:

Real STAT interrupt is available

Continuous operation:

Additional sample setting during operation

Sample cooling:

Not available

Sample Container Types

Primary tubes:

5 - 10 mL; 16 x 100; 16 x 75; 13 x 100; 13 x 75 mm

Sample cup:

2.5 mL

Micro cup:

1.5 mL

Cups on tube:

Cup on top of a 16 x 75/100 mm tube

Sample Volume

2.0 - 16.5 µL in 0.25 µL steps

Sample Dilution

1.2 - 100 times

Sample Clot Detection

Not available

Minimum Sample Volume

Primary tubes:

500 µL

Sample cup:

75 µL

Micro cup:

75 µL

System Interfaces

RS–232 serial interface, bi-directional

Sample Data Base

100 routine/STAT samples, 360 test results

QC Analysis

QC history provides QC results of current and previous calendar month
Graphic analysis of results over time

Rerun

Manual rerun with predefined dilution

Electrical Requirements

Power requirements:

100 - 125V and 200 - 240V (-15% to +10%)
250 VA (320 VA with ISE)

Frequency:

50 Hz or 60 Hz ± 0.5%

Water/Waste Requirements

Minimum:

Reagent Grade NCCLS Type II

Recommended:

Reagent Grade NCCLS Type I

Water consumption:

10 mL per measurement

Water temperature:

15° - 30° C

Biohazards waste:

Separate container

Operating Conditions

Ambient temperature

15° - 32° C

Ambient humidity

30 - 80% (RH, without condensation))

Heat Output

Maximum 320 kcal/h

Noise Output

<70 dB(A) for surrounding

Physical Dimensions

Width:

28.4 in

(720 mm)

Depth:

21.7 in

(550 mm)

Height:

18.9 in

(480 mm)

Weight

85.1 lbs (38.6 kg)



Please have a Roche representative contact me!

Microsoft and Windows are trademarks of Microsoft Corporation.
Pentium is a trademark of Intel Corporation.
COBAS, COBAS INTEGRA, LIFE NEEDS ANSWERS, and MYLABONLINE are trademarks of Roche.


Copyright © Roche Diagnostics, North America.
See our Legal Statement, Privacy Statement, and Trademark Info.
Webmaster
Current as of:  
This website contains information on products which is targeted to a wide range of audiences and could contain product details or information otherwise not accessible or valid in your country. Please be aware that we do not take any responsibility for accessing such information which may not comply with any valid legal process, regulation, registration or usage in the country of your origin.
Search
Advanced
Technical Documentation
Login
Need to register?
Forgot my password
Privacy Statement